T1 (2 Port) Multi-Flex Trunk WAN Card Errors & Clocking

by arul on June 22, 2010

Deploying VWIC-2MFT-T1 cards in various routers & are experiencing errors & drops. Does anyone know if there are any known issues w/these cards? Also, regarding clocking, is there a particular way these cards should be configured, e.g. if there are 4 T1s on the router, only one of them can be configured as “clock source internal” & the rest MUST be “clock source line”?
Thanks in advance for your feedback!

{ 2 comments… read them below or add one }

Kumar June 22, 2010 at 9:32 pm

We had the same issues on 2821 router with 12.4 IOS. Here is the solution i recieved from TAC.
Looks like we were hitted by the bug CSCsb00129 (LCV and PCV errors increment on VWIC-2MFT and VWIC-1MFT).
In order to solve the issue I need you to please downgrade to this IOS version and let me know the results: c2800nm-ipvoice-mz.123-11.T7.bin.

karan June 22, 2010 at 9:32 pm

Unfortunately that same bug ID indicates that the problem was supposed to be fixed in 12.4(3) but since I am still having the same problem I guess it is not. Back to 12.3 code.

Previous post:

Next post: